Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Data Brief ; 47: 108854, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36798599

RESUMO

The present work exhibits the dynamic viscosity profile data of three distinct nanofluids, at a constant shear stress, and within a range of temperatures that include below-ambient conditions (from -10 to 20 °C). The nanofluids were as follows. Nanofluid I: 30% ethylene glycol and 70% distilled water (v/v), with graphene (0.32% in mass); Nanofluid II: 30% engine coolant NBR 13705; ASTM D-3306; ASTM D-4985) and 70% distilled water (v/v), with graphene (0.2% in mass); and Nanofluid III: 30% engine coolant and 70% distilled water (v/v), with Multi-Walled Carbon Nanotubes (MWCNT) (0.2% in mass). The present work was motivated by the scarcity of experimental data on the temperature dependence of viscosity for graphene, MWCNT, and their hybrid nanofluids, at below-ambient temperatures.

2.
Ciênc. rural (Online) ; 52(1): e20200908, 2022. tab
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1339653

RESUMO

ABSTRACT: Eggshell quality is directly linked to the good acceptability of the product by consumers, whereas the industry is concerned with economic losses. Prolonged periods of laying, diseases, nutrition, bird age and genetics can influence egg quality. This study aimed to examine the influence of the environment, bird age and storage period on the physical characteristics of the shell of eggs from commercial laying hens. The experiment involved 288 eggs from Hy-line hens, which were distributed in a completely randomized design with a triple 3×2×4 factorial arrangement represented by three ages (31, 62 or 88 weeks), two storage temperatures (ambient or refrigerated), and four storage periods (one, 10, 20 or 30 days), totaling 24 treatments. Four replications were used with three eggs each. Eggshell strength, percentage and thickness were measured. Differences were observed, with the eggs stored at room temperature exhibiting lower shell strength. Laying eggs at an advanced age (88 weeks) resulted in decreased eggshell strength as compared with the other ages, whereas the eggs from young layers (31 weeks) had a thicker shell. The advancing age of the laying hens reduced eggshell quality, regardless of the storage environment. Nonetheless, the eggs stored in the refrigerator showed better eggshell quality and integrity than those stored at ambient temperature.


RESUMO: A qualidade da casca está diretamente ligada à boa aceitabilidade do produto pelos consumidores, enquanto a indústria se preocupa com as perdas econômicas. Períodos prolongados de postura, doenças, nutrição, idade da ave e genética podem influenciar a qualidade dos ovos. Objetivou-se avaliar a influência do ambiente, idade da ave e período de armazenamento nas características físicas da casca de ovos de poedeiras comerciais. Foram utilizados 288 ovos de poedeiras Hy-line, distribuídos em um delineamento inteiramente casualizado em fatorial triplo 3x2x4, sendo os fatores: três idades (31, 62 e 88 semanas), temperatura de armazenamento (ambiente e refrigerado), e quatro períodos de armazenamento (um, 10, 20 e 30 dias), totalizando 24 tratamentos, com quatro repetições de três ovos. Avaliou-se a resistência, percentual e espessura da casca. Foram observadas diferenças, uma vez que os ovos armazenados em temperatura ambiente apresentaram diminuição na resistência de casca. Ovos de poedeiras em idade avançada (88 semanas) apresentaram pior resistência de casca em relação às demais idades, enquanto ovos provenientes de poedeiras jovens (31 semanas) apresentaram maior espessura de casca. A idade avançada da poedeira reduziu a qualidade de casca dos ovos, independentemente do ambiente de armazenamento. Ainda, os ovos armazenados em geladeira apresentaram melhor qualidade e integridade da casca em comparação com os armazenados ao ambiente.

3.
Preprint em Português | SciELO Preprints | ID: pps-2421

RESUMO

Objective: To describe the adequacy of immunobiological conservation in the immunization rooms of the Western macro-region of Minas Gerais, Brazil. Methods: Descriptive study from a validated scale with a maximum score of 15 points. Descriptive analysis and association test between the scores obtained by the municipalities and variables of the external context were performed. Results: 275 out of a total of 295 immunization rooms were evaluated. The conservation of immunobiologicals in the macro-region obtained a mean score of 4 points (4/15). The absence or lack of inputs for the conservation of immunobiologicals and work processes requiring improvement was noted. Small municipalities presented better conservation of immunobiologicals (p=0.011). Conclusion: The immunobiological conservation in the immunization rooms of the macroregion West of Minas Gerais was considered inadequate.


Objetivo: Descrever a adequação da conservação de imunobiológicos nas salas de imunização dos municípios da macrorregião de saúde Oeste do estado de Minas Gerais, Brasil. Métodos: Estudo descritivo, pautado em uma escala validada, com escore máximo de 15 pontos. Realizou-se análise descritiva e teste de associação entre os escores obtidos pelos municípios e variáveis do contexto externo. Resultados: Foram avaliadas 275 do total de 295 salas de imunização existentes. A conservação de imunobiológicos na macrorregião Oeste obteve um escore médio de 4 pontos (escore-padrão de 0 a 15). Evidenciou-se ausência ou carência de insumos destinados à conservação de imunobiológicos, e processos de trabalho que requerem aprimoramento. Municípios de pequeno porte apresentaram melhor conservação de imunobiológicos (p=0,011). Conclusão: A conservação de imunobiológicos nas salas de imunização da macrorregião de saúde Oeste de Minas Gerais foi considerada inadequada.

4.
Av. enferm ; 39(2): 178-187, 01 may 2021.
Artigo em Português | LILACS, BDENF - Enfermagem, COLNAL | ID: biblio-1290949

RESUMO

Objetivo: compreender o significado da conservação de vacinas e do cuidado na sala de vacinação para a equipe de enfermagem de unidades de atenção primária à saúde. Materiais e métodos: estudo qualitativo, sob o olhar e a perspectiva da fenomenologia social de Alfred Schütz, realizado em março de 2018, por meio de entrevista aberta com profissionais de enfermagem atuantes na sala de vacinação. Resultados: com base na análise das entrevistas, os resultados foram organizados em três categorias: Manter a conservação de vacinas é cuidar da qualidade e da segurança, Agir no presente e pensar no futuro e Sala de vacinação ideal. Os profissionais compreendem a importância da conservação de vacinas pautada na qualidade, na segurança e na demanda por melhorias na estruturação das salas de vacinação. Conclusões: a equipe de enfermagem percebe a necessidade de manter a cadeia de frio de conservação dos imunobiológicos em todas as instâncias, com expectativas e desejos de aquisição de equipamentos, para melhorar a estrutura física e a oferta de cuidado empático a fim de prevenir doenças.


Objetivo: comprender el significado de la conservación de las vacunas y los cuidados en la sala de vacunación para el personal de enfermería de las unidades de atención primaria. Materiales y métodos: estudio cualitativo, desde la perspectiva de la fenomenología social de Alfred Schütz, realizado en marzo de 2018 mediante entrevistas abiertas a profesionales de enfermería que trabajan en salas de vacunación. Resultados: a partir del análisis de las entrevistas, los resultados se organizaron en tres categorías: Mantener la conservación de las vacunas es cuidar la calidad y la seguridad, Actuar en el presente y pensar en el futuro y Sala de vacunación ideal. Los profesionales comprenden la importancia de la conservación de las vacunas en función de la calidad, la seguridad y la demanda por mejoras en la estructura de las salas de vacunación. Conclusiones: el equipo de enfermería percibe la necesidad de mantener la cadena de frío de la conservación inmunobiológica en todas las instancias, con expectativas y deseos de adquirir equipos, mejorar la estructura física y ofrecer cuidados empáticos para prevenir enfermedades.


Objective: To understand the meaning of vaccine conservation and vaccination room care for the nursing staff of primary health care units. Materials and methods: Qualitative study, under the perspective of Alfred Schütz's social phenomenology, conducted in March 2018 through an open interview with nursing professionals working at a vaccination room. Results: Based on the analysis of the interviews, results were organized in three categories: Maintaining vaccine conservation is taking care of quality and safety, Acting in the present and thinking about the future, and Ideal vaccination room. The professionals understand the importance of vaccine conservation based on quality and safety standards, and thus demand improvements in the structure of vaccination rooms. Conclusions: Nursing teams perceive the need to maintain the cold chain of conservation of immunobiologicals in all instances, with expectations and desires towards the acquisition of equipment, improvements in the physical structure of vaccination rooms, and, therefore, offering a more empathic care in order to prevent diseases.


Assuntos
Humanos , Atenção Primária à Saúde , Refrigeração , Vacinas , Pesquisa Qualitativa , Equipe de Enfermagem
5.
Epidemiol. serv. saúde ; 30(3): e20201017, 2021. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1286360

RESUMO

Objetivo: Descrever a adequação da conservação de imunobiológicos nas salas de imunização dos municípios da macrorregião de saúde Oeste do estado de Minas Gerais, Brasil. Métodos: Estudo descritivo, pautado em uma escala validada, com escore máximo de 15 pontos. Realizou-se análise descritiva e teste de associação entre os escores obtidos pelos municípios e variáveis do contexto externo. Resultados: Foram avaliadas 275 do total de 295 salas de imunização existentes. A conservação de imunobiológicos na macrorregião Oeste obteve um escore médio de 4 pontos (escore-padrão de 0 a 15). Evidenciou-se ausência ou carência de insumos destinados à conservação de imunobiológicos, e processos de trabalho que requerem aprimoramento. Municípios de pequeno porte apresentaram melhor conservação de imunobiológicos (p=0,011). Conclusão: A conservação de imunobiológicos nas salas de imunização da macrorregião de saúde Oeste de Minas Gerais foi considerada inadequada.


Objetivo: Describir la adecuación de la conservación de inmunobiológicos en las salas de inmunización de la macrorregión Oeste de Minas Gerais, Brasil. Métodos: Estudio descriptivo a partir de una escala validada con una puntuación máxima de 15 puntos. Se realizaron análisis descriptivos y pruebas de asociación entre las puntuaciones obtenidas por los municipios y las variables del contexto externo. Resultados: Se evaluaron 275 de un total de 295 salas de vacunación. La conservación de los inmunobiológicos en la macrorregión Oeste obtuvo una puntuación promedio de 4 puntos (4/15). Se evidenció la ausencia o falta de insumos para la conservación de inmunobiológicos y procesos de trabajo que requieren ser mejorados. Los municipios pequeños presentaron una mejor conservación de los inmunobiológicos (p=0,011). Conclusión: La conservación inmunobiológica en las salas de vacunación de la macrorregión Oeste de Minas Gerais fue considerada inadecuada.


Objective: To describe the adequacy of immunobiological agent conservation in vaccination rooms in the municipalities of the Western health macro-region of the state of Minas Gerais, Brazil. Methods: This was a descriptive study, based on a validated scale, with a maximum score of 15 points. A descriptive analysis and an association test between the scores obtained by the municipalities and variables of the external context were performed. Results: 275 out of a total of 295 existing vaccination rooms were evaluated. Immunobiological agent conservation in the West macro-region obtained an average score of 4 points (standard score, 0 to 15). There was a poor availability of immunization supplies aimed at immunobiological agent conservation, and work processes, that require improvement. Small municipalities presented better immunobiological agent conservation (p=0.011). Conclusion: Immunobiological agent conservation in vaccination rooms in the Western health macro-region of Minas Gerais State was considered inadequate.


Assuntos
Humanos , Vacinas/provisão & distribuição , Imunização/instrumentação , Refrigeração/instrumentação , Brasil
6.
Rev. bras. enferm ; 74(1): e20190762, 2021. tab, graf
Artigo em Inglês | LILACS, BDENF - Enfermagem | ID: biblio-1155944

RESUMO

ABSTRACT Objectives: to analyze vaccine losses in a Health Region in the Northwest of São Paulo. Methods: retrospective cross-sectional study with secondary data obtained from Temperature Change Notification Forms used by the Epidemiological Surveillance Group XXIX of São José do Rio Preto between 2010 and 2017. Descriptive and inferential analysis were performed using multiple linear regression and significance level of 95%. Results: in total, 341 notifications of temperature changes were analyzed, of which 70.1% were caused by structural reasons, 57.8% in industrial refrigerators and 91.2% in primary care services. Of the doses that suffered a change in temperature, 41.4% were lost and 58.6% were administered to the population. The highest percentage of lost doses compared to those applied occurred in smaller municipalities, although they reported less. Conclusions: nursing workers who work in vaccination rooms should make efforts to prevent temperature changes and avoid losses and higher public expenses.


RESUMEN Objetivos: analizar las pérdidas de vacunas en una Región de Salud del Noroeste de São Paulo. Métodos: estudio transversal retrospectivo, con datos secundarios obtenidos de los formularios de notificación de cambios de temperatura utilizados por el Grupo XXIX de Vigilancia Epidemiológica de São José do Rio Preto entre 2010 y 2017. Se realizó el análisis descriptivo e inferencial y se utilizó la regresión lineal múltiple y nivel de significancia del 95%. Resultados: se analizaron 341 notificaciones de cambios de temperatura, de las cuales el 70,1% fueron por motivos estructurales, el 57,8% en frigoríficos industriales y el 91,2% en los servicios de atención primaria. De las dosis que sufrieron un cambio de temperatura, el 41,4% se perdieron y el 58,6% se administraron a la población. El mayor porcentaje de dosis perdidas en comparación con las aplicadas se produjo en los municipios más pequeños, aunque informaron menos. Conclusiones: los trabajadores de enfermería que laboran en las salas de vacunación deben esforzarse por prevenir cambios de temperatura, evitando pérdidas y aumento de los gastos públicos.


RESUMO Objetivos: analisar as perdas de vacinas em uma Região de Saúde do Noroeste paulista. Métodos: estudo transversal retrospectivo, com dados secundários obtidos das fichas de notificação de alteração de temperatura utilizadas pelo Grupo de Vigilância Epidemiológica XXIX de São José do Rio Preto, entre 2010 e 2017. Foi realizada análise descritiva e inferencial, utilizando regressão linear múltipla e nível de significância de 95%. Resultados: foram analisadas 341 notificações de alteração de temperatura, sendo 70,1% causadas por motivos estruturais, 57,8% em refrigeradores industriais e 91,2% em serviços de atenção básica. Das doses que sofreram alteração de temperatura, 41,4% foram perdidas e 58,6% foram administradas na população. O maior percentual de doses perdidas em relação às aplicadas ocorreu em municípios menores, apesar de eles notificarem menos Conclusões: os trabalhadores de enfermagem que atuam em salas de vacinação devem se empenhar para prevenir alterações de temperatura, evitando perdas e aumento dos gastos públicos.


Assuntos
Humanos , Vacinas , Temperatura , Brasil , Vacinas/efeitos adversos , Estudos Transversais , Estudos Retrospectivos , Cidades
7.
Arq. bras. med. vet. zootec. (Online) ; 72(5): 1989-1992, Sept.-Oct. 2020.
Artigo em Português | LILACS, VETINDEX | ID: biblio-1131572

RESUMO

The morphological characteristics of the autologous platelet concentrate (APC) of 31 dogs were evaluated after cooling and freezing in 6% DMSO. Blood from the jugular vein of each patient was collected and centrifuged at 191g for six minutes to obtain APC. In the fresh sample, the platelet count, MPV, PDW and cell morphology were evaluated. Four samples of each animal were sent for storage, one refrigerated at 4°C for seven days, another for 30 days and two more stored in a freezer at -80°C in the same time interval, using 6% DMSO as cryoprotectant. The conserved samples were submitted to the same laboratory analysis as the fresh sample. There was a difference between fresh and preserved samples for platelet count, cell concentration, MPV and PDW (P<0.05), except in the 30-day refrigerated group, which showed severe morphological changes. In the frozen group for seven days, no difference was observed in the percentage of activation (P>0.05). The results obtained lead to the conclusion that cryopreservation with 6% DMSO at -80°C for seven days is a favorable option for the maintenance of platelet concentrations and the morphological characteristics of APC in dogs.(AU)


Assuntos
Animais , Cães , Refrigeração , Criopreservação , Plasma Rico em Plaquetas/citologia , Dimetil Sulfóxido
8.
Saude e pesqui. (Impr.) ; 13(3): 475-483, jul.-set. 2020.
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1140633

RESUMO

O objetivo deste trabalho éavaliar a qualidade da conservação das vacinas em Unidades da Atenção Primária à Saúde em uma capital do Nordeste brasileiro. Trata-se de um estudo descritivo e avaliativo, transversal, com abordagem quantitativa. Aplicou-se parte do instrumento PAISSV 2.0 do Programa Nacional de Imunização, com profissionais da enfermagem entre agosto de 2016 e janeiro de 2017. Utilizou-se análise estatística descritiva. Avaliou-se 48 (92,3%) salas de vacinas. Na dimensão estrutura, destaca-se a ausência de câmaras refrigeradas e de instrumentos de monitoramento e controle da temperatura em 100% das salas avaliadas. Quanto ao processo de conservação, evidenciou-se que nenhuma das salas realizava a distribuição das vacinas nas prateleiras, conforme recomendações técnicas. 43 (89,6%) salas foram classificadas como não adequadas e nenhuma considerada adequada. A prática da conservação de vacinas ainda é incipiente, com inadequação da estrutura e processo de trabalho. Estas lacunas podem comprometer a erradicação e o controle das doenças imunopreveníveis.


The preservation of vaccines in Primary Health Care units in São Luís, a capital city in northeastern Brazil, is evaluated. Current descriptive, evaluative, cross-sectional quantitative approach was applied to a section of PAISSV 2.0 of the National Immunization Program with nursing professionals, between August 2016 and January 2017. Descriptive statistical analysis was employed. Forty-eight (92.3%) vaccine rooms were assessed. The complete absence of refrigerated chambers and the lack of monitoring and control instruments for temperature may be highlighted. In the case of the conservation process, not a single vaccine room distributed vaccines on shelves as recommended. Further, 43 vaccine rooms (89.6%) were classified as unsuitable and all were inappropriate. The vaccine conservation practice is still incipient, with inadequate structure and working process. These flaws may compromise the eradication and control of immunopreventive diseases.

9.
Av. enferm ; 38(2): 170-181, May-Aug. 2020. tab, graf
Artigo em Inglês | COLNAL, BDENF - Enfermagem, LILACS | ID: biblio-1114687

RESUMO

Abstract Objective: To develop and to test the validity of content and layout of a multidimensional tool to evaluate maintenance of the cold chain for immunobiological conservation. Method: A methodological study carried out in three steps: integrative review; development of theoretical and logical model for the development of the tool; implementation of the Delphi Technique to test the validity of content and layout. The Content Validity Index (CVI) and Content Validity Ratio (CVR) were calculated considering appropriate those values greater than or equal to 75% and 0.4, respectively. Results: The instrument consisted of 7 questions about structure and 20 about process, subdivided into three components: Transportation/Reception (n=3); Storage/Handling (n=13); Supervision/Permanent education (n=4). The cvi value was 87.4%, with values equal to 85.7% and 89% in the structure and process dimensions, respectively. The process components obtained cvi values equal to 88.9, 88.9 and 89.2%, respectively. The CVR was 0.8, with values equal to 0.7 and 0.8 in the structure and process dimensions. As for the layout validation, the questionnaire was considered intelligible. Conclusion: The study provides an instrument with validity of content and layout for health professionals in charge of the supervision of activities of immunobiological conservation, ensuring the maintenance of the immunogenic quality of the products offered to the population.


Resumen Objetivo: desarrollar y validar los contenidos e interface de una herramienta multidimensional para evaluar el mantenimiento de la cadena de frío de la conservación inmunobiológica. Método: estudio metodológico realizado en tres pasos: revisión integradora; elaboración de modelo teórico y lógico para el desarrollo de la herramienta; implementación de la técnica Delphi para la validación de contenido y de apariencia de preguntas. Se calcularon el Índice de validez de contenido (IVC) y el Razón de Validez de Contenido (RVC), considerando apropiados aquellos valores mayores o iguales al 75 % y 0,4, respectivamente. Resultados: el cuestionario constaba de siete preguntas de estructura y 20 de proceso, subdivididas en tres componentes: Transporte/Recepción (n=3); Almacenamiento/Manipulación (n=13); Supervisión/Educación continua (n=4). El valor para el cvi fue 87,4 %, con valores iguales al 85,7 y 89 % en las dimensiones estructura y proceso, respectivamente. Los componentes del proceso obtuvieron valores para el IVC iguales a 88,9, 88,9 y 89,2 %, respectivamente. El RVC era una herramienta de 0,8, con valores iguales a 0,7 en la estructura de dimensión y 0,8 en proceso. En cuanto a la validación de la apariencia, el cuestionario se consideró inteligible. Conclusión: el estudio proporciona un instrumento con contenido validado para profesionales de la salud, en la supervisión de actividades de conservación de productos inmunobiológicos, asegurando el mantenimiento de la calidad inmunogénica de los productos ofrecidos a la población.


Resumo Objetivo: desenvolver e validar o conteúdo e interface de um instrumento multidimensional para avaliar a manutenção da cadeia de frio de conservação de imunobiológicos. Método: estudo metodológico realizado em três etapas: revisão integrativa; elaboração do modelo teórico-lógico para o desenvolvimento do instrumento; realização da Técnica Delphi para validar conteúdo e aparência das questões. Foram calculados o Índice de Validade de Conteúdo (IVC) e a Razão de Validade de Conteúdo (RVC), considerando-se valores adequados aqueles maiores ou iguais a 75 % e 0,4, respectivamente. Resultados: o questionário constou de sete questões de estrutura e 20 de processo, subdivididos em três componentes: transporte/recebimento (n=3); armazenamento/manuseio (n=13); supervisão/educação permanente (n=4). O valor para o IVC foi de 87,4 %, com valores iguais a 85,7 % na dimensão estrutura e 89 % no processo. Os componentes do processo obtiveram valores para o IVC iguais a 88,9 %, 88,9 % e 89,2 %, respectivamente. O RVC do instrumento foi de 0,8, com valores iguais a 0,7 na dimensão estrutura e 0,8 no processo. Quanto à validação de aparência, o questionário foi considerado inteligível. Conclusão: o estudo fornece um instrumento de medida com conteúdo validado e que se configura em uma ferramenta de gestão útil na supervisão de salas de imunização.


Assuntos
Humanos , Refrigeração , Vacinas , Avaliação de Programas e Projetos de Saúde , Estudo de Validação , Equipamentos e Provisões
10.
ABCS health sci ; 45: [1-6], 02 jun 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1097547

RESUMO

INTRODUCTION: Immunobiologicals are of great importance for the prevention and eradication of diseases. However, the lack of maintenance of the cold chain generates several problems related to losses of these substances, burdening an important amount of public resources. OBJECTIVE: To analyze vaccine losses in a Health Region (Região Ampliada de Saúde Oeste) of Minas Gerais State in Brazil. METHODS: This is a descriptive study, based on secondary data obtained through forms used by the regional health agency (Superintendência Regional de Saúde, SRS), to register losses of immunobiologicals due to temperature changes. Forms from February 2016 through January 2018 were analyzed. The data was organized and validated by double typing. RESULTS: Vaccine losses were caused by lack of electrical energy (40.83%), followed by equipment failure (36.67%), and professional error (10%). As a consequence, 17,229 bottles of vaccines (65.78%) were discarded, corresponding to 111,145 doses. The financial loss was R$ 604,340.31. CONCLUSION: Losses of vaccines due to temperature changes were relevant in the studied region, damaging the budget for the local health network. Therefore, it is suggested that measures to minimize these losses should be adopted.


INTRODUÇÃO: Os imunobiológicos são de grande importância para a prevenção e erradicação de doenças. Entretanto, a falta de manutenção da Rede de Frio gera diversos problemas relacionados a perdas dessas substâncias, onerando uma importante quantia de recursos públicos. OBJETIVO: Analisar as perdas vacinais da Região Ampliada de Saúde Oeste de Minas Gerais. MÉTODOS: Trata-se de um estudo descritivo, com base em dados secundários obtidos através de formulários utilizados pela Superintendência Regional de Saúde (SRS), para avaliação de perdas de imunobiológicos por alteração de temperatura. Foram analisados os formulários de fevereiro de 2016 até janeiro de 2018. Os dados foram organizados e validados por dupla digitação, e a análise foi feita descritivamente. RESULTADOS: Os resultados mostraram que dos motivos das ocorrências 40,83% foram por falta de energia elétrica, seguida de falha no equipamento (36,67%), e erro do profissional (10%). Foram inutilizados 17229 frascos de vacinas (65,78%), sendo 111.145 doses, com uma perda financeira de R$ 604.340,31. CONCLUSÃO: Identificou-se que as perdas físicas por alteração de temperatura de vacinas na região estudada foram relevantes, gerando prejuízos para o orçamento do SUS. Dessa forma sugere-se a adoção de condutas para minimizar estas perdas.


Assuntos
Refrigeração , Temperatura , Vacinas/provisão & distribuição
11.
Pesqui. vet. bras ; 40(4): 306-314, Apr. 2020. tab
Artigo em Inglês | VETINDEX, LILACS | ID: biblio-1135625

RESUMO

The objective of this study was to evaluate the sperm quality obtained of domestic cats by electroejaculation and recovery of the tail of the epididymis after cooling at -1°C and 4°C for 24 and 48 hours. Twenty-nine adult cats (2 to 6kg) were used. Sperm collection was performed by electroejaculation (EEJ), and after 48 hours, the cats were orchiectomized, and sperm sample was obtained from the vas deferens and epididymis tail (EPD). The samples were diluted in ACP-117® extender, and the sperm characteristics were evaluated at three different moments: when still fresh, 24 and 48 hours after cooling. The objective of this study was to evaluate the sperm quality obtained of domestic cats by electroejaculation and recovery of the tail of the epididymis after cooling at -1°C and 4°C for 24 and 48 hours. Twenty-nine adult cats (2 to 6kg) were used. Sperm collection was performed by electroejaculation (EEJ), and after 48 hours, the cats were orchiectomized, and sperm sample was obtained from the vas deferens and epididymis tail (EPD). The samples were diluted in ACP-117® extender, and the sperm characteristics were evaluated at three different moments: when still fresh, 24 and 48 hours after cooling. In order to compare the two refrigeration temperatures, the first stage was to analyze if there was a difference between the harvesting techniques. After this, two experiments were conducted: in the first, sperm sample from 14 cats were used and the cooling was performed at -1°C; and in the second, sample from 15 cats were used and the sperm were refrigerated at 4°C. Sperm kinetics were evaluated by computerized analysis (CASA) and concentration by Neubauer chamber, spermatic morphology was evaluated by modified Karras staining, and membrane integrity was evaluated by eosin nigrosine. The results obtained were analyzed in R software, version 3.2.5 using the Mann-Whitney test for variables with abnormal distributions, considering significance at the level of 5%. In ejaculate samples, higher values of total morphological defects were observed after 24 and 48 hours of refrigeration at 4°C (P<0.022) compared to refrigeration at -1°C, using Friedman test. To quantify the decrease in sperm quality, parameter reductions were calculated among time points (F-24h/F-48h/24h-48h). In EPD samples, a greater reduction in sperm quality was detected after 24 hours of refrigeration at 4°C, both in motility and sperm kinetics and in the movement and velocity indices, compared to refrigeration at -1°C. Based on the results, it can be concluded that cooling of feline spermatozoa at -1°C for up to 48 hours was efficient in maintaining spermatic quality collected by EEJ and EPD, and it could be an alternative to spermatozoa cryopreservation in domestic felines.(AU)


O objetivo deste trabalho foi avaliar a qualidade espermática de gatos domésticos obtidos por eletroejaculação e recuperação da cauda do epidídimo após a refrigeração a -1°C e a 4°C por 24 e 48 horas. Vinte e nove gatos adultos (2 a 6kg) foram utilizados. A colheita de espermatozoides foi realizada por eletroejaculação (EEJ) e, após 48 horas, os gatos foram orquiectomizados, e as amostras espermáticas foram obtidas a partir do ducto deferente e da cauda do epidídimo (EPD). As amostras foram diluídas em ACP-117® e as características espermáticas foram avaliadas em três momentos distintos: fresco, 24 e 48 horas após a refrigeração. Para ser possível comparar as duas temperaturas de refrigeração, a primeira etapa foi analisar se havia diferença entre as técnicas de colheita. Após isto, dois experimentos foram conduzidos: no primeiro, espermatozoides de 14 gatos foram utilizados e a refrigeração foi realizada a -1°C; e no segundo, amostras de 15 gatos foram utilizados e os espermatozoides foram refrigerados a 4°C. A cinética espermática foi avaliada por análise computadorizada (CASA), a concentração por câmara de Neubauer, a morfologia espermática foi avaliada pela coloração de Karras modificada, e a integridade da membrana foi avaliada por eosina nigrosina. Os resultados obtidos foram analisados no software R, versão 3.2.5, utilizando o teste de Mann-Whitney para variáveis com distribuições anormais, considerando significância ao nível de 5%. No ejaculado, maiores valores de defeitos morfológicos totais foram observados após 24 e 48 horas de refrigeração a 4°C (P<0,022) em comparação com refrigeração a -1°C, usando o teste de Friedman. Para quantificar a diminuição na qualidade espermática, as reduções dos parâmetros foram calculadas entre os pontos de tempo (F-24h/F-48h/24h-48h). Na EPD, uma maior redução na qualidade espermática foi detectada após 24 horas de refrigeração a 4°C, tanto na motilidade e na cinética espermática quanto nos índices de movimento e velocidade, em comparação com a refrigeração a -1°C. Com base nos resultados, pode concluir-se que a refrigeração dos espermatozoides felino a -1°C, até 48 horas, foi eficaz na manutenção da qualidade espermático colhidos por EEJ e EPD, e pode ser uma alternativa para a criopreservação de espermatozoides em felinos domésticos.(AU)


Assuntos
Animais , Masculino , Gatos , Sêmen , Preservação do Sêmen/veterinária , Espermatozoides , Criopreservação , Técnicas de Reprodução Assistida , Técnicas de Reprodução Assistida/veterinária , Epididimo
12.
Epidemiol. serv. saúde ; 29(2): e2019004, 2020. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1101125

RESUMO

Objetivo: descrever as perdas físicas, por descarte, dos imunobiológicos fornecidos pelo Programa Nacional de Imunizações (PNI) ao estado do Ceará no período 2014-2016, e os custos das doses perdidas. Métodos: estudo descritivo, com dados dos formulários de avaliação de imunobiológicos sob suspeita e dos pareceres favoráveis de descarte. Resultados: foram incluídos 317 formulários, dos quais 72,0% obtiveram parecer de descarte; foram identificadas 160.767 doses perdidas, totalizando um custo de R$ 1.834.604,75; as perdas representaram 0,45%, 0,93% e 0,53% do custo total das vacinas nos anos de 2014, 2015 e 2016, respectivamente; o principal motivo das perdas físicas identificadas foi a falta de energia elétrica (54,9%). Conclusão: identificou-se grande número de doses descartadas por perdas físicas, com elevado custo absoluto; faz-se necessário um controle mais rigoroso, pois falhas na dinâmica de conservação podem interferir na oferta dos imunobiológicos.


Objetivo: describir las pérdidas físicas por eliminación de inmunobiológicos proporcionados por el Programa Nacional de Inmunización (PNI) al estado de Ceará, en el periodo 2014-2016, y los costos de las dosis omitidas. Métodos: estudio descriptivo, con datos de formula-rios de evaluación de los inmunobiológicos sospechosos y de las opiniones favorables de descarte. Resultados: se incluyeron un total de 317 formularios, de los cuales el 72,0% obtuvo una opinión de descarte, y se identificaron 160.767 dosis omitidas, con un costo total de R$ 1.834.604,75; las pérdidas representaron el 0,45%, el 0,93% y el 0,53% del costo total de las vacunas en 2014, 2015 y 2016, respectivamente; la razón principal de las pérdidas físicas identificadas fue la falta de electricidad (54,9%). Conclusión: iden-tificamos un gran número de dosis descartadas por pérdidas físicas, con un alto costo absoluto; es necesario un control más estricto, ya que las fallas en la dinámica de conser-vación pueden interferir con el suministro de inmunobiológicos.


Objective: to describe discarded wasted immunobiological products provided by the National Im-munization Program (PNI) to the State of Ceará between 2014 and 2016, and the costs of discarded doses. Methods: this was a descriptive study using data from suspect im-munobiological product evaluation forms and data from disposal approval forms. Results: a total of 317 forms were included, 72.0% of which had a disposal approval form, and 160,767 discarded doses were identified, at a total cost of BRL 1,834,604.75; wastage accounted for 0.45%, 0.93% and 0.53% of the total cost of vaccines in 2014, 2015 and 2016, respectively; the main reason for the wastage identified was electric power shortage (54.9%). Conclusion: we identified a large number of discarded wasted doses, with high absolute cost; tighter control is necessary, as failures in conservation dynamics may interfere with the supply of immunobiologicals.


Assuntos
Humanos , Vacinas/administração & dosagem , Vacinação/estatística & dados numéricos , Eliminação de Resíduos de Serviços de Saúde/estatística & dados numéricos , Programas de Imunização/organização & administração , Brasil , Epidemiologia Descritiva , Armazenamento de Medicamentos/normas
13.
Rev. bras. enferm ; 72(3): 671-679, May.-Jun. 2019. tab
Artigo em Inglês | BDENF - Enfermagem, LILACS | ID: biblio-1013552

RESUMO

ABSTRACT Objective: to construct collectively with nursing professionals bundle for best practices of cold chain maintenance of immunobiological agents conservation at the local level. Method: a qualitative research of convergent care type. Bundle construction was guided by the Evidence-Based Practice criterion. Data collection was carried out from October to December 2016, through five workshops, with the participation of 21 professionals from 7 vaccination rooms of a municipality of Minas Gerais State. The framework developed by Morse and Field was adopted for data analysis. Results: through bundle, care is taken regarding refrigeration equipment temperature monitoring, contingency plan performance, recyclable ice coil setting and chamber use as refrigeration equipment. Final considerations: the chosen interventions began to guide the practice and promote a care based on safety and quality.


RESUMEN Objectivo: construir colectivamente, con profesionales de enfermería, bundle para buenas prácticas de mantenimiento de la cadena de frío de conservación de inmunobiológicos a nivel local. Método: investigación cualitativa del tipo convergente asistencial. La construcción del bundle fue guiada por los criterios de la Práctica Basada en Evidencias. La recolección de datos fue realizada en el período de octubre a diciembre de 2016, por medio de cinco talleres, con la participación de 21 profesionales de 7 salas de vacunación de un municipio del estado de Minas Gerais. Para el análisis de los datos, se adoptó el referencial de Morse y Field. Resultados: por medio del bundle, se contemplan cuidados relativos al monitoreo de la temperatura del equipo de refrigeración, ejecución del plan de contingencia, ambientación de la bobina de hielo reciclable y el uso de la cámara como equipo de refrigeración. Consideraciones finales: las intervenciones elegidas pasaron a guiar la práctica y promover un cuidado pautado en la seguridad y calidad.


RESUMO Objetivo: construir coletivamente, com profissionais de enfermagem, bundle para boas práticas de manutenção da cadeia de frio de conservação de imunobiológicos em nível local. Método: pesquisa qualitativa do tipo convergente assistencial. A construção do bundle foi norteada pelos critérios da Prática Baseada em Evidências. A coleta de dados foi realizada no período de outubro a dezembro de 2016, por meio de cinco oficinas, com a participação de 21 profissionais de 7 salas de vacinação de um município de Minas Gerais. Para análise dos dados, adotou-se o referencial de Morse e Field. Resultados: por meio do bundle, contemplam-se cuidados relativos ao monitoramento da temperatura do equipamento de refrigeração, execução do plano de contingência, ambientação da bobina de gelo reciclável e o uso da câmara como equipamento de refrigeração. Considerações finais: as intervenções eleitas passaram a nortear a prática e promover um cuidado pautado na segurança e qualidade.


Assuntos
Humanos , Masculino , Feminino , Adulto , Refrigeração/métodos , Vacinas/uso terapêutico , Pacotes de Assistência ao Paciente/métodos , Refrigeração/normas , Competência Clínica/normas , Guias de Prática Clínica como Assunto , Pesquisa Qualitativa , Enfermagem Baseada em Evidências/métodos , Pessoa de Meia-Idade
14.
Hig. aliment ; 33(288/289): 628-632, abr.-maio 2019.
Artigo em Português | LILACS, VETINDEX | ID: biblio-1482010

RESUMO

O objetivo deste trabalho foi avaliar o efeito de biofilmes comestíveis na conservação de abóbora minimamente processada, mantida sob refrigeração a 4°C ± 1°C durante 9 dias. O delineamento experimental foi inteiramente casualizado com três repetições, em esquema fatorial 6x3, onde o primeiro se refere a 6 tipos de biofilmes comestíveis e 3 tempos de armazenamento (3,6,9). Observou-se através das análises realizadas que quando comparada o amido de mandioca com batata, a utilização de biofilmes comestíveis produzidos através da batata variedade Duda foi mais efetiva na preservação das características físicas e físico-químicas da abóbora minimamente processada.


Assuntos
Alimentos Resfriados , Biofilmes , Conservação de Alimentos , Cucurbita/química , Armazenamento de Alimentos , Fenômenos Químicos
15.
Pesqui. vet. bras ; 39(5): 332-341, May 2019. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1012753

RESUMO

Knowledge about reproduction of white-lipped peccary is of great importance to assist with the conservation of this species and enable its rational use in captivity. This study aimed to evaluate the effect of ACP-103®, ACP-116® and BTS semen extenders on sperm viability during cooling of Tayassu pecari semen. Five ejaculates from four adult males were chilled. The animals were submitted to the protocols of sedation and anesthesia for semen collection by the electroejaculation method. After collection, the semen was macro- and microscopically assessed and diluted to reach 35x106 spermatozoa/mL in each of the three different extenders tested. The fresh-extended semen was packed in a BotuFLEX® thermal box to keep samples at 15°C for 24 hours. After cooling, the following semen parameters were analyzed: sperm motility, functional and structural integrity of sperm membranes, mitochondrial activity, chromatin condensation, and the thermoresistance test was performed. The parameters sperm motility, structural and functional integrity of sperm membranes, mitochondrial activity, and chromatin condensation were preserved after use of the extenders tested, and were similar to those of in natura semen (p>0.05). Curvilinear velocity (VCL) (p<0.05) was the only parameter with reduced values after cooling regardless of the extender used. The percentage of sperm with normal morphology was greater in samples cooled using the BTS extender (p<0.05). The ACP-103®, ACP-116® and BTS extenders can be used for the cooling and preservation of white-lipped peccary semen at 15°C for 24 hours.(AU)


Para auxiliar na conservação da espécie e permitir o uso racional do queixada em cativeiro é de grande importância o conhecimento sobre a reprodução da espécie. Objetivou-se avaliar o efeito dos diluidores de sêmen ACP-103®, ACP-116® e BTS na viabilidade espermática durante a refrigeração do sêmen do Tayassu pecari. Foram refrigerados cinco ejaculados provenientes de quatro machos adultos. Os animais foram contidos com auxílio de puçá e submetidos ao protocolo de sedação e anestesia para realização da coleta de sêmen pelo método da eletroejaculação. Depois da coleta, o sêmen foi avaliado macro e microscopicamente e diluído para atingir 35x106 espermatozoides/mL em cada um dos três diferentes diluidores testados. O sêmen diluído foi acondicionado em caixa térmica BotuFLEX® para manter as amostras a 15°C por um período de 24 horas. Depois da refrigeração, os espermatozoides foram avaliados quanto aos parâmetros de movimento espermático, integridade funcional e estrutural das membranas espermáticas, atividade mitocondrial, condensação da cromatina e teste de termorresistência. Os diluidores testados preservaram as características cinéticas, a integridade estrutural e funcional das membranas espermáticas, a atividade mitocondrial e a condensação da cromatina semelhante ao sêmen in natura (P>0,05). O único parâmetro que reduziu com o processo de refrigeração independente do diluidor utilizado foi a Velocidade Curvilinear (VCL) (P<0,05). Foi observado aumento do percentual de espermatozoides morfologicamente normais nas amostras refrigeradas em BTS (P<0,05). Os diluidores ACP-103®, ACP-116® e BTS podem refrigerar e conservar o sêmen de queixada a 15°C por 24 horas.(AU)


Assuntos
Animais , Artiodáctilos , Preservação do Sêmen/métodos , Anafilaxia Cutânea Passiva , Criopreservação/veterinária
16.
Arq. Inst. Biol ; 86: e1212018, 2019. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1024562

RESUMO

In this study, we investigated the contamination of refrigerated raw milk produced in the western region of Paraná, southern Brazil, with psychrotrophic microorganisms, aiming to assay the proteolytic activity of the isolates and to identify Pseudomonas fluorescens, the main proteolytic species associated with the spoilage of milk products. Raw milk samples from 50 dairy farms were submitted to the counting of psychrotrophic microorganisms, being the microbiota characterized by its mesophilic behavior and proteolytic capacity, besides molecular identification of P. fluorescens. Of the samples evaluated, 94% had psychrotrophic counts ranging from 3 to 7.1 log CFU mL-1, and 48.5% of these showed mesophilic behavior. Of the isolates, 48.0% had proteolytic activity in at least one evaluated temperature (21 and 30°C), and 39.3% had proteolytic activity in both temperatures. Among the 61 isolates submitted to molecular identification by polymerase chain reaction (PCR), 86.8% contained the expression of the 16S gene characteristic for P. fluorescens. In this study, we demonstrated that P. fluorescens is the most prevalent psychrotrophic bacteria species in raw refrigerated milk and their proteolytic ability poses high risks to the dairy industry.(AU)


No presente estudo, investigamos a contaminação do leite cru refrigerado produzido na região oeste do Paraná, sul do Brasil, com micro-organismos psicrotróficos, visando testar a atividade proteolítica dos isolados e identificar Pseudomonas fluorescens, a principal espécie proteolítica associada à deterioração de produtos lácteos. Amostras de leite cru de 50 fazendas leiteiras foram submetidas à contagem de micro-organismos psicrotróficos, caracterizando-se a microbiota por seu comportamento mesofílico e sua capacidade proteolítica, além de identificação molecular de P. fluorescens. Entre as amostras avaliadas, 94% apresentaram contagem psicrotrófica variando de 3 a 7,1 log UFC mL-1 e 48,5% destas apresentaram comportamento mesofílico. Entre os isolados, 48,0% apresentaram atividade proteolítica em pelo menos uma das temperaturas testadas (21 e 30°C) e 39,3% apresentaram atividade proteolítica em ambas as temperaturas. Entre os 61 isolados sub-metidos à identificação molecular por reação em cadeia da polimerase (PCR), 86,8% continham expressão do gene 16S característico de P. fluorescens. Neste estudo, demonstramos que P. fluorescens é a espécie de bactérias psicrotróficas mais prevalente em leite refrigerado cru e sua capacidade proteolítica promove elevados riscos de deterioração para a indústria de laticínios.(AU)


Assuntos
Pseudomonas fluorescens , Leite , Proteólise , Bactérias , Contaminação de Alimentos , Reação em Cadeia da Polimerase , Alimentos Resfriados
17.
Saúde debate ; 42(116): 203-213, jan.-mar. 2018. tab, graf
Artigo em Português | LILACS | ID: biblio-962638

RESUMO

RESUMO Objetivou-se identificar a ocorrência de perdas evitáveis de imunobilógicos em um município, no período de 2011 a 2015, e conhecer o processo de trabalho da equipe de enfermagem na Rede de Frio (RF). Trata-se de um estudo de caso do tipo exploratório documental e de campo, com abordagem quantitativa e qualitativa. Os dados foram extraídos dos Sistemas de Informações de Apuração de Imunobiológicos Utilizados (SI-AIU) e do Programa Nacional de Imunização (PNI) e coletados em 54 entrevistas com profissionais de enfermagem. Das ocorrências evitáveis, destaca-se a perda por validade vencida (83%). Algumas estratégias de enfrentamento foram propostas, com destaque para gerenciamento de lotes na instância superior.


ABSTRACT The objective of this study was to identify the occurrence of avoidable losses of immunologicals in a municipality, in the period from 2011 to 2015, and to know the work process of the nursing team in the Cold Network. It is a case study of the documental exploratory and field type, with quantitative and qualitative approach. Data were extracted from the Information Systems of Verification of Immunobiological Used (SI-AIU) and from the National Immunization Program (PNI), and collected in 54 interviews with nursing professionals. Of the avoidable occurrences, it is highlighted the loss due to expired validity (83%). Some coping strategies were proposed, with emphasis on batch management in the higher instance.

18.
Ciênc. rural (Online) ; 48(8): e20180078, 2018. tab
Artigo em Inglês | LILACS | ID: biblio-1045177

RESUMO

ABSTRACT: Preservation and use of spermatozoa that have been recovered after death can extend the use of genetically superior animals. The objective of this study was to evaluate the maximum period for which ovine spermatozoa could be successfully stored in refrigerated dilution medium post-mortem, with or without added seminal plasma. Three samples of spermatozoa collected in an artificial vagina from 10 rams, or from the tails of four epididymes from the same rams at the time of death (G0) and six (G6), twelve (G12), twenty-four (G24) and forty-eight (G48) hours after death were used. After recovery, the spermatozoa were refrigerated at 5°C in either control medium (CM) or control medium plus 20%homologous seminal plasma (SP) and evaluated for 72 hours from the start of refrigeration. The G48 samples had a lower(P <0.05) total motility (TM) and plasma membrane integrity in the hyposmotic test (HOST) than the other groups evaluated at all analyzed times. The TM decreased (P <0.05) after 24 hours of cooling in semen collected in AV, at G0 and G24 and after 48 hours of refrigeration in G6 and G12. The TM and HOST integrity and sperm morphology did not differ between samples refrigerated in CM or SP. In conclusion, it is possible to collect epididymal spermatozoa up to 24 hours after death. Sperm viability can be prolonged fora further 48 hours by refrigeration. However, total motility decreases from 24 hours after refrigeration and the supplementation of 20% seminal plasma to the extender has no effect on spermatozoa longevity.


RESUMO: A recuperação e preservação dos espermatozoides após a morte possibilita maior aproveitamento de animais geneticamente superiores. O objetivo deste trabalho foi avaliar o período máximo após a morte do carneiro para que os espermatozoides possam ser refrigerados em meio diluidor com ou sem plasma seminal. Foram utilizadas três amostras de espermatozoides colhidos em vagina artificial (AV) de 10 carneiros ou da cauda de quatro epidídimos provenientes dos mesmos carneiros no momento da morte (G0) e seis (G6), doze (G12), vinte e quatro (G24) e quarenta e oito (G48) horas após a morte. Após a recuperação os espermatozoides (em AV ou cauda do epidídimo) foram refrigerados à 5°C em dois tratamentos: meio controle (CM) ou meio controle acrescido de 20% de plasma seminal homólogo (SP) e avaliados até 72 horas após o início da refrigeração. As amostras do G48 apresentaram motilidade total (TM) e integridade de membrana plasmática no teste hiposmótico (HOST) menor (P<0,05) que os outros grupos avaliados em todos os momentos estudados. TM diminuiu (P<0,05) após 24 horas de refrigeração no sêmen colhido em AV, no G0 e G24 e a partir de 48 horas de refrigeração no G6 e G12. A TM, integridade de membrana no HOST e morfologia espermática não diferiram entre as amostras refrigeradas em CM ou SP. Contudo, é possível refrigerar espermatozoides epididimários até 24 horas post mortem, a refrigeração prolonga a viabilidade espermática até 48 horas após o início da refrigeração. A adição de 20% de plasma seminal ao meio diluidor não tem efeito sobre a longevidade espermática.

19.
Rev. bras. cir. plást ; 32(4): 562-569, out.-dez. 2017. ilus, tab
Artigo em Inglês, Português | LILACS | ID: biblio-878778

RESUMO

Introdução: Enxertos de pele autólogos são utilizados em tratamento de pacientes queimados. Esses enxertos podem ser armazenados e preservados, desde que o processo de armazenamento seja realizado com rígido controle de qualidade, para garantir a redução dos riscos de infecção. Métodos: Foi realizado um estudo de coorte retrospectivo na Unidade de Queimados do Hospital das Clínicas de São Paulo no período de fevereiro de 2015 a julho de 2016, em que foi estabelecido um protocolo para armazenamento de pele refrigerada com controle de coleta, preservação, embalagem e registro de todos os processos. Para garantia de qualidade, foram coletadas biópsias dos enxertos para microbiologia pré e pós-armazenamento e realizado um estudo transversal de prevalência de contaminação pré e pós-estocagem. Resultados: Os pontos críticos encontrados foram inadequação de embalagem, ausência de registros de processos, falta de coleta de biópsias para microbiologia e falhas no descarte. A maior parte das amostras estava contaminada tanto pré como pós-estocagem (84,2%). Apenas dois pacientes apresentaram microbiologia estéril no pré e contaminada no pós, porém foram encontrados germes da pele do tipo gram+. Conclusão: Foi estabelecido um método promissor de armazenamento de pele refrigerada que necessita alguns pequenos ajustes para adequação ao controle de qualidade.


Introduction: Autologous skin grafts are used for treatment of burn patients. These grafts can be stored and preserved, as long as the storage process is performed with strict quality control to reduce the risk of infection. Methods: A retrospective cohort study was conducted in the Burn Unit of the Hospital das Clínicas de São Paulo from February 2015 to July 2016. During this period, a protocol was established to store refrigerated skin, with control of collection, preservation, and packaging, and recording of all processes. To ensure quality, graft biopsies were collected for pre- and poststorage microbiology testing and a cross-sectional study for contamination was performed. Results: Critical deficiencies included inadequate packaging, lack of processing records, lack of biopsies for microbiology testing, and failure to discard specimens. Most of the samples were contaminated before and after storage (84.2%). Only two samples were sterile before storage but became contaminated after storage, with growth of Gram-positive skin bacteria. Conclusion: A promising method for the storage of refrigerated skin was established, but requires minor adjustments in quality control.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , História do Século XXI , Controle de Qualidade , Refrigeração , Preservação de Tecido , Transplante Autólogo , Estudos Retrospectivos , Transplante de Pele , Refrigeração/métodos , Preservação de Tecido/métodos , Transplante Autólogo/legislação & jurisprudência , Transplante Autólogo/métodos , Transplante de Pele/legislação & jurisprudência , Transplante de Pele/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...